Error Code 7003

Supporting Labview 2012 and up
danenorman13
Fresh meat
Posts: 1
Joined: Wed Jul 21, 2021 3:48 pm

Error Code 7003

Post by danenorman13 »

Hello All,
I am working with the VINT Hub Phidget and the 1131 Force Sensors. I have followed all of the LabView based informal instruction on the Phidgets help page and have dug into the sub VI Phidget Common.lvlib/_Open(dot)vi to trace a connection error. I have not been able to talk to my force sensor or hub at all using LabView. I can use the Phidget Control Panel so I do know everything is working.

NI Max does not recognize the hardware, I am coming up with zero ideas on how to get LabView to talk to the Hub/sensors.

Any help is appreciated.
You do not have the required permissions to view the files attached to this post.
jdecoux
Engineering
Posts: 184
Joined: Mon Nov 13, 2017 10:20 am

Re: Error Code 7003

Post by jdecoux »

To connect a Ratiometric sensor like the 1131 on a VINT Hub, you will need to set the IsHubPort parameter to True from the corresponding VoltageRatioInputStart.VI
You do not have the required permissions to view the files attached to this post.