by berkinet
Tue Aug 17, 2021 12:52 pm
Forum: All Other Phidgets
Topic: Versatile Input Freq Counter and 5V Sensors
Replies: 4
Views: 12973

Re: Versatile Input Freq Counter and 5V Sensors

I have the same question. Unfortunately, the PSU2000 is not carried by the local dealer here in France. However, I was wondering if I could just use a vint port as the 5v source. Much as the analog ifKit ports can be used to power a relay.
by berkinet
Tue Aug 17, 2021 10:11 am
Forum: Python
Topic: Sensor value is ouside the valid range...
Replies: 13
Views: 31600

Re: Sensor value is ouside the valid range...

The numbers you gave match up almost perfectly: 0.535 v/v -> 57.766 °C on the 1125's temperature sensor (or 1124) 0.535 v/v -> 61.771 %RH on the 1125's humidity sensor... You were right. I must have not been paying close enough attention and had selected the humidity sensor. Sorry for wasting your ...
by berkinet
Tue Aug 17, 2021 10:09 am
Forum: All Other Phidgets
Topic: 1054 input question
Replies: 2
Views: 8232

Re: 1054 input question

mparadis wrote:If it's a mechanical relay you might be seeing some contact bounce which would mess with the frequency signal.
Indeed. This did the trick... Thanks.
circuit2.png
circuit2.png (28.69 KiB) Viewed 8135 times
by berkinet
Mon Aug 16, 2021 10:46 am
Forum: Python
Topic: Sensor value is ouside the valid range...
Replies: 13
Views: 31600

Re: Sensor value is ouside the valid range...

Nope. It is set as a temperature device. I am measuring the exit pipe on a hot water system.
by berkinet
Sun Aug 15, 2021 9:59 am
Forum: All Other Phidgets
Topic: 1054 input question
Replies: 2
Views: 8232

1054 input question

I am using a relay to switch the 5vdc source from a 1054 frequency counter back to its positive input. The negative input is tied to the onboard ground. And there is a 4.7k ohm resistor between positive input and ground (pull-down). The displayed input frequency can be around 0.5hz or around 4h.z Ho...
by berkinet
Mon Aug 09, 2021 1:23 pm
Forum: Python
Topic: Sensor value is ouside the valid range...
Replies: 13
Views: 31600

Re: Sensor value is ouside the valid range...

A little additional information on my preceding post. At the time the range error was reported, the 1124 was showing a temperature around 57° (0.535 V/V) in the Phidget Control Panel. With no errors being reported. Interestingly, if the phidget is actually open in the control panel, I do not see the...
by berkinet
Mon Aug 09, 2021 10:56 am
Forum: Python
Topic: Sensor value is ouside the valid range...
Replies: 13
Views: 31600

Re: Sensor value is ouside the valid range...

While we are on the subject (and in the context of another thread I started. I find that with the 1124/1125 analog temperature sensors the initial sensorValue sent after setting sensorType always yields this error:

Code: Select all

Sensor value is ouside the valid range for this sensor.
Any ideas?
by berkinet
Mon Aug 09, 2021 10:41 am
Forum: Python
Topic: Get sensor info from libs
Replies: 6
Views: 18852

Re: Get sensor info from libs

Perfect!
by berkinet
Mon Aug 09, 2021 10:39 am
Forum: Python
Topic: Sensor value is ouside the valid range...
Replies: 13
Views: 31600

Re: Sensor value is ouside the valid range...

Thanks!!
by berkinet
Mon Aug 09, 2021 10:07 am
Forum: Python
Topic: P22 on a R-Pi question
Replies: 9
Views: 24418

Re: P22 on a R-Pi question

:-(