Resets the failsafe timer, if one has been set. See enableFailsafe()
for details.
This function will fail if no failsafe timer has been set for the channel.
1011_0 (ver: 100, 101, 102, 103) Digital Output : Supported
1012_0 (ver: 600) Digital Output : Supported
1012_0 (ver: 601) Digital Output : Supported
1012_0 (ver: 602, 603, 604) Digital Output : Supported
1012_1 (ver: 605) Digital Output : Supported
1012_2 (ver: 605) Digital Output : Supported
1012_3 (ver: 606) Digital Output : Supported
1013_0 (ver: 800, 811, 820) Digital Output : Supported
1013_0 (ver: 821, 823) Digital Output : Supported
1018_0 (ver: 824, 825, 826) Digital Output : Supported
1018_1 (ver: 826) Digital Output : Supported
1019_0 (ver: 826) Digital Output : Supported
1070_0 (ver: 826) Digital Output : Supported
1014_0 (ver: 700) Power Relay : Supported
1014_0 (ver: 704, 705, 706) Power Relay : Supported
1014_1 (ver: 707) Power Relay : Supported
1014_2 (ver: 707) Power Relay : Supported
1017_0 (ver: 100) Signal Relay : Supported
1017_1 (ver: 100) Signal Relay : Supported
1010_0 (ver: 903, 904) Digital Output : Supported
1018_2 (ver: 900, 901, 902, 903, 904) Digital Output : Supported
1019_1 (ver: 903, 904) Digital Output : Supported
1072_0 (ver: 903) Digital Output : Supported
1073_0 (ver: 904) Digital Output : Supported
1018_3 (ver: 1000) Digital Output : Supported
1023_0 (ver: 200) Digital Output : Supported
1023_0 (ver: 200) LED Driver : Supported
1023_0 (ver: 200) Onboard LED : Supported
1023_0 (ver: 201, 202, 203, 204) Digital Output : Supported
1023_1 (ver: 205, 206) Digital Output : Supported
1023_0 (ver: 201, 202, 203, 204) LED Driver : Supported
1023_1 (ver: 205, 206) LED Driver : Supported
1023_0 (ver: 201, 202, 203, 204) Onboard LED : Supported
1023_1 (ver: 205, 206) Onboard LED : Supported
1024_0 (ver: 100, 101, 103) Digital Output : Supported
1024_0 (ver: 100, 101, 103) LED Driver : Supported
1024_0 (ver: 100, 101, 103) Onboard LED : Supported
1030_0 (ver: 100, 101, 200, 201, 202) LED Driver : Supported
1031_0 (ver: 100, 101) LED Driver : Supported
1032_0 (ver: 200, 201) LED Driver : Supported
1202_0 (ver: 100) Digital Output : Supported
1203_0 (ver: 100) Digital Output : Supported
1202_0 (ver: 120, 121) Digital Output : Supported
1202_1 (ver: 123, 124) Digital Output : Supported
1203_0 (ver: 120, 121) Digital Output : Supported
1203_1 (ver: 123, 124) Digital Output : Supported
1202_2 (ver: 200, 201, 202, 203, 204) Digital Output : Supported
1203_2 (ver: 200, 201, 202, 203, 204) Digital Output : Supported
1219_0 (ver: 110, 111, 113) Digital Output : Supported
1220_0 (ver: 110, 111, 113) Digital Output : Supported
1221_0 (ver: 110, 111, 113) Digital Output : Supported
1222_0 (ver: 110, 111, 113) Digital Output : Supported
HUB0000_0 (ver: 117, 118, 119) Digital Output : Supported
HUB0000_0 (ver: 121, 125, 126, 127) Digital Output : Supported
HUB5000_0 (ver: 100) Digital Output : Supported
HUB5000_0 (ver: 102, 104, 105, 106) Digital Output : Supported
SBC3003_0 (ver: 101, 102) Digital Output : Supported
SBC3003_0 (ver: 108, 109, 110) Digital Output : Supported
HUB0000_0 (ver: 307) Digital Output : Supported
HUB0001_0 (ver: 111) Digital Output : Supported
HUB5000_0 (ver: 107) Digital Output : Supported
HUB5000_0 (ver: 203) Digital Output : Supported
SBC3003_0 (ver: 203) Digital Output : Supported
OUT1100_0 (ver: 100) Digital Output : Supported
OUT1100_0 (ver: 110) Digital Output : Supported
OUT1100_0 (ver: 120) Digital Output : Supported
LED1000_0 (ver: 104, 105) LED Driver : Supported
REL1000_0 (ver: 101) Power Relay : Supported
REL1000_0 (ver: 110, 120) Power Relay : Supported
REL1100_0 (ver: 100) Digital Output Isolated : Supported
REL1100_0 (ver: 110) Digital Output Isolated : Supported
REL1100_0 (ver: 120) Digital Output Isolated : Supported
REL1101_0 (ver: 102) Digital Output Isolated : Supported
REL1101_0 (ver: 110, 111, 120) Digital Output Isolated : Supported
REL1101_1 (ver: 100, 200, 201, 212) Digital Output Isolated Frequency Control : Supported
REL1101_1 (ver: 100, 200, 201, 212) Digital Output Isolated : Supported
|
Device In Device # Identification |
|
error in (no error) error in can accept error information wired from VIs previously called. |
|
status status is TRUE (X) if an error occurred or FALSE (checkmark) to indicate a warning or that no error occurred. Right-click the error in control on the front panel and select Explain Error or Explain Warning from the shortcut menu for more information about the error. |
|
code code is the error or warning code. Right-click the error in control on the front panel and select Explain Error or Explain Warning from the shortcut menu for more information about the error. |
|
source source describes the origin of the error or warning. Right-click the error in control on the front panel and select Explain Error or Explain Warning from the shortcut menu for more information about the error. |
|
Device Out Same as Device In |
|
error out error out passes error or warning information out of a VI to be used by other VIs. |
|
status status is TRUE (X) if an error occurred or FALSE (checkmark) to indicate a warning or that no error occurred. Right-click the error out control on the front panel and select Explain Error or Explain Warning from the shortcut menu for more information about the error. |
|
code code is the error or warning code. Right-click the error out control on the front panel and select Explain Error or Explain Warning from the shortcut menu for more information about the error. |
|
source source describes the origin of the error or warning. Right-click the error out control on the front panel and select Explain Error or Explain Warning from the shortcut menu for more information about the error. |