Phidget Voltage Input.lvlib:VoltageInputSensorEventExe.vi

The most recent sensor value the channel has measured will be reported in this event, which occurs when the DataInterval has elapsed.

Phidget Voltage Input.lvlib:VoltageInputSensorEventExe.vi

Device Support:

1011_0 (ver: 100, 101, 102, 103) Voltage Input : Supported

1013_0 (ver: 800, 811, 820) Voltage Input : Supported

1013_0 (ver: 821, 823) Voltage Input : Supported

1018_0 (ver: 824, 825, 826) Voltage Input : Supported

1018_1 (ver: 826) Voltage Input : Supported

1019_0 (ver: 826) Voltage Input : Supported

1070_0 (ver: 826) Voltage Input : Supported

1010_0 (ver: 903, 904) Voltage Input : Supported

1018_2 (ver: 900, 901, 902, 903, 904) Voltage Input : Supported

1019_1 (ver: 903, 904) Voltage Input : Supported

1072_0 (ver: 903) Voltage Input : Supported

1073_0 (ver: 904) Voltage Input : Supported

1048_0 (ver: 100, 101, 102) Voltage Input : Unsupported

1051_0 (ver: 200, 201, 202) Voltage Input : Unsupported

1051_1 (ver: 300) Voltage Input : Unsupported

1051_2 (ver: 400, 401, 402) Voltage Input : Unsupported

1058_0 (ver: 100, 101) Voltage Input : Unsupported

1065_0 (ver: 100, 101) Voltage Input : Supported

1065_1 (ver: 100, 101) Voltage Input : Supported

1065_0 (ver: 100, 101) Supply Voltage Sensor : Unsupported

1065_1 (ver: 100, 101) Supply Voltage Sensor : Unsupported

1202_0 (ver: 100) Voltage Input : Supported

1203_0 (ver: 100) Voltage Input : Supported

1202_0 (ver: 120, 121) Voltage Input : Supported

1202_1 (ver: 123, 124) Voltage Input : Supported

1203_0 (ver: 120, 121) Voltage Input : Supported

1203_1 (ver: 123, 124) Voltage Input : Supported

1202_2 (ver: 200, 201, 202, 203, 204) Voltage Input : Supported

1203_2 (ver: 200, 201, 202, 203, 204) Voltage Input : Supported

HUB0000_0 (ver: 117, 118, 119) Voltage Input : Supported

SBC3003_0 (ver: 101, 102) Voltage Input : Supported

HUB0000_0 (ver: 121) Voltage Input : Supported

HUB5000_0 (ver: 102) Voltage Input : Supported

SBC3003_0 (ver: 108) Voltage Input : Supported

ADP1000_0 (ver: 104) Voltage Input : Supported

DAQ1000_0 (ver: 102, 103) Voltage Input : Supported

DAQ1000_0 (ver: 110) Voltage Input : Supported

DAQ1400_0 (ver: 112) Voltage Input : Unsupported

SAF1000_0 (ver: 101, 102) Voltage Sensor : Unsupported

TMP1100_0 (ver: 103, 105) Voltage Input : Unsupported

TMP1101_0 (ver: 104, 106) Voltage Input : Unsupported

VCP1000_0 (ver: 100) Voltage Input : Unsupported

VCP1001_0 (ver: 100) Voltage Input : Unsupported

VCP1002_0 (ver: 106) Voltage Input : Unsupported

cerrcodeclst

error in (no error)

error in can accept error information wired from VIs previously called.

c1du64

Devices In

A list of devices registered for the same type of event

ceventregrn

Event Registration Refnum In

Event # Identification

ierrcodeclst

error out

error out passes error or warning information out of a VI to be used by other VIs.

ibool

Event?

Returns TRUE if the event has executed, or FALSE otherwise.

i1du64

Devices Out

Same as Devices In

ii32

Index

The index of the device that triggered the event within the Devices In array.

idbl

Sensor Value

The sensor value

iu64

phid

Device # Identification of the device that triggered the event.

ieventregrn

Event Registration Refnum Out

Same as Event Registration Refnum In