The controller will not issue a CurrentChange
event until the current value has changed by the amount specified by the CurrentChangeTrigger
.
CurrentChangeTrigger
to 0 will result in the controller firing events every DataInterval
. This is useful for applications that implement their own data filtering
|
Device In Device # Identification |
|
error in (no error) error in can accept error information wired from VIs previously called. |
|
status status is TRUE (X) if an error occurred or FALSE (checkmark) to indicate a warning or that no error occurred. Right-click the error in control on the front panel and select Explain Error or Explain Warning from the shortcut menu for more information about the error. |
|
code code is the error or warning code. Right-click the error in control on the front panel and select Explain Error or Explain Warning from the shortcut menu for more information about the error. |
|
source source describes the origin of the error or warning. Right-click the error in control on the front panel and select Explain Error or Explain Warning from the shortcut menu for more information about the error. |
|
Trigger The change trigger value Units: amperes (A) 1061_0 (ver: 100) RC Servo Motor Current Sensor: Min: 0 Max: 1 Def: 0
1061_0 (ver: 200) RC Servo Motor Current Sensor: Min: 0 Max: 1 Def: 0
1061_1 (ver: 300, 301, 302, 303, 304) RC Servo Motor Current Sensor: Min: 0 Max: 1 Def: 0
1063_0 (ver: 100) Bipolar Stepper Current Sensor: Min: 0 Max: 1 Def: 0 1063_1 (ver: 100, 101) Bipolar Stepper Current Sensor: Min: 0 Max: 1 Def: 0
1064_0 (ver: 100, 101, 102) DC Motor Current Sensor: Min: 0 Max: 1 Def: 0 1064_1 (ver: 102) DC Motor Current Sensor: Min: 0 Max: 1 Def: 0
1065_0 (ver: 100, 101) DC Motor Current Sensor: Min: 0 Max: 1 Def: 0
1066_0 (ver: 100) RC Servo Motor Current Sensor: Min: 0 Max: 1 Def: 0 1066_1 (ver: 100, 101) RC Servo Motor Current Sensor: Min: 0 Max: 1 Def: 0
DAQ1400_0 (ver: 100) Current Input: Min: 0 Max: 0.016 Def: 0
DCC1000_0 (ver: 100) Current Sensor: Min: 0 Max: 25Val: 0 |
|
Device Out Same as Device In |
|
error out error out passes error or warning information out of a VI to be used by other VIs. |
|
status status is TRUE (X) if an error occurred or FALSE (checkmark) to indicate a warning or that no error occurred. Right-click the error out control on the front panel and select Explain Error or Explain Warning from the shortcut menu for more information about the error. |
|
code code is the error or warning code. Right-click the error out control on the front panel and select Explain Error or Explain Warning from the shortcut menu for more information about the error. |
|
source source describes the origin of the error or warning. Right-click the error out control on the front panel and select Explain Error or Explain Warning from the shortcut menu for more information about the error. |