The DataInterval
is the time that must elapse before the controller will fire another TemperatureChange
event.
MinDataInterval
and MaxDataInterval
.TemperatureChange
events can also affected by the TemperatureChangeTrigger
.
|
Device In Device # Identification |
|
error in (no error) error in can accept error information wired from VIs previously called. |
|
status status is TRUE (X) if an error occurred or FALSE (checkmark) to indicate a warning or that no error occurred. Right-click the error in control on the front panel and select Explain Error or Explain Warning from the shortcut menu for more information about the error. |
|
code code is the error or warning code. Right-click the error in control on the front panel and select Explain Error or Explain Warning from the shortcut menu for more information about the error. |
|
source source describes the origin of the error or warning. Right-click the error in control on the front panel and select Explain Error or Explain Warning from the shortcut menu for more information about the error. |
|
Interval The data interval value Units: milliseconds (ms) 1045_0 (ver: 100, 101) Temperature Sensor (IR): Min: 32 Max: 60000 Def: 256 1045_1 (ver: 101) Temperature Sensor (IR): Min: 32 Max: 60000 Def: 256
1045_0 (ver: 100, 101) Temperature Sensor (IC): Min: 32 Max: 60000 Def: 256 1045_1 (ver: 101) Temperature Sensor (IC): Min: 32 Max: 60000 Def: 256
1048_0 (ver: 100, 101, 102) Thermocouple Input: Min: 32 Max: 60000 Def: 256
1048_0 (ver: 100, 101, 102) Temperature Sensor (IC): Min: 32 Max: 60000 Def: 256
1051_0 (ver: 100) Thermocouple Input: Min: 32 Max: 60000 Def: 256
1051_0 (ver: 100) Temperature Sensor (IC): Min: 32 Max: 60000 Def: 256
1051_0 (ver: 200, 201, 202) Thermocouple Input: Min: 32 Max: 60000 Def: 256
1051_0 (ver: 200, 201, 202) Temperature Sensor (IC): Min: 32 Max: 60000 Def: 256
1051_1 (ver: 300) Thermocouple Input: Min: 32 Max: 60000 Def: 256
1051_1 (ver: 300) Temperature Sensor (IC): Min: 32 Max: 60000 Def: 256
1051_2 (ver: 400, 401, 402) Thermocouple Input: Min: 32 Max: 60000 Def: 256
1051_2 (ver: 400, 401, 402) Temperature Sensor (IC): Min: 32 Max: 60000 Def: 256
DCC1000_0 (ver: 100) Temperature Sensor: Min: 500 Max: 60000Val: 500
HUM1000_0 (ver: 100) Temperature Sensor: Min: 500 Max: 60000 Def: 500
SAF1000_0 (ver: 100) Temperature Sensor: Min: 100 Max: 60000 Def: 250
TMP1000_0 (ver: 100) Temperature Sensor (IC): Min: 500 Max: 60000Val: 500
TMP1100_0 (ver: 100) Thermocouple Input: Min: 20 Max: 60000 Def: 250
TMP1100_0 (ver: 100) Temperature Sensor (IC): Min: 300 Max: 60000 Def: 500
TMP1101_0 (ver: 100) Thermocouple Input: Min: 20 Max: 60000 Def: 250
TMP1101_0 (ver: 100) Temperature Sensor (IC): Min: 300 Max: 60000 Def: 500
TMP1200_0 (ver: 100) RTD input: Min: 250 Max: 60000 Def: 250
TMP1300_0 (ver: 100) Temperature Sensor (IR): Min: 20 Max: 60000 Def: 250
TMP1300_0 (ver: 100) Temperature Sensor (IC): Min: 20 Max: 60000 Def: 250 |
|
Device Out Same as Device In |
|
error out error out passes error or warning information out of a VI to be used by other VIs. |
|
status status is TRUE (X) if an error occurred or FALSE (checkmark) to indicate a warning or that no error occurred. Right-click the error out control on the front panel and select Explain Error or Explain Warning from the shortcut menu for more information about the error. |
|
code code is the error or warning code. Right-click the error out control on the front panel and select Explain Error or Explain Warning from the shortcut menu for more information about the error. |
|
source source describes the origin of the error or warning. Right-click the error out control on the front panel and select Explain Error or Explain Warning from the shortcut menu for more information about the error. |